• HCPL-V454

    ฿ 520
    Features • 12-bit Linearity • 200 ns Conversion Time (Pre-Trigger Mode 2 with HCPL-0872) • 12-bit Effective Resolution with 5 μs Signal Delay (14-bit with 102 μs) (with HCPL-0872) • Fast 3 μs Over-Range Detection (with HCPL-0872) • ± 200 mV Input Range with Single 5 V Supply • 1% Internal Reference Voltage Matching • Offset Calibration (with HCPL-0872) • -40°C to +85°C Operating Temperature Range • 15 kV/μs Isolation Transient Immunity • Safety Approval: UL 1577, CSA and IEC/EN/DIN EN 60747-5-5 Applications • Motor Phase and Rail Current Sensing • Data Acquisition Systems • Industrial Process Control • Inverter Current Sensing • General Purpose Current Sensing and Monitoring
  • HCPL-7840

    ฿ 480

    Features

    • 15 kV/ms Common-Mode Rejection at VCM = 1000 V
    • Compact, Auto-Insertable Standard 8-pin DIP Package
    • 0.00025 V/V/ degrees C Gain Drift vs. Temperature
    • 0.3 mV Input Offset Voltage
    • 100 kHz Bandwidth
    • 0.004% Nonlinearity
    • Worldwide Safety Approval: UL 1577 (3750 Vrms/1 min.) and CSA (pending), IEC/EN/DIN EN 60747-5-2 (option 060 only)
    • Advanced Sigma-Delta (S-D) A/D Converter Technology
    • Fully Differential Circuit Topology
    • 0.8 mm CMOS IC Technology
    • Options available are:
    No Option = Standard DIP package, 50 per tube 060 = IEC/EN/DIN EN 60747-5-2 Option 300 = Surface Mount Option 500 = Tape/Reel Packaging Option, 1 k min. per reel XXXE = Lead Free Option

    Applications

    • Motor Phase and Rail Current Sensing
    • Inverter Current Sensing
    • DC Bus Voltage Sensing
    • Switched Mode Power Supply Signal Isolation
    • General Purpose Current Sensing and Monitoring
    • General Purpose Analog Signal Isolation
    • Traditional Hall Effect Sensor Replacement
  • HCPL-786J

    ฿ 520
    Features • 12-bit Linearity • 200 ns Conversion Time (Pre-Trigger Mode 2 with HCPL-0872) • 12-bit Effective Resolution with 5 μs Signal Delay (14-bit with 102 μs) (with HCPL-0872) • Fast 3 μs Over-Range Detection (with HCPL-0872) • ± 200 mV Input Range with Single 5 V Supply • 1% Internal Reference Voltage Matching • Offset Calibration (with HCPL-0872) • -40°C to +85°C Operating Temperature Range • 15 kV/μs Isolation Transient Immunity • Safety Approval: UL 1577, CSA and IEC/EN/DIN EN 60747-5-5 Applications • Motor Phase and Rail Current Sensing • Data Acquisition Systems • Industrial Process Control • Inverter Current Sensing • General Purpose Current Sensing and Monitoring
  • HCPL-7860

    ฿ 520
    Features • 12-bit Linearity • 200 ns Conversion Time (Pre-Trigger Mode 2 with HCPL-0872) • 12-bit Effective Resolution with 5 μs Signal Delay (14-bit with 102 μs) (with HCPL-0872) • Fast 3 μs Over-Range Detection (with HCPL-0872) • ± 200 mV Input Range with Single 5 V Supply • 1% Internal Reference Voltage Matching • Offset Calibration (with HCPL-0872) • -40°C to +85°C Operating Temperature Range • 15 kV/μs Isolation Transient Immunity • Safety Approval: UL 1577, CSA and IEC/EN/DIN EN 60747-5-5 Applications • Motor Phase and Rail Current Sensing • Data Acquisition Systems • Industrial Process Control • Inverter Current Sensing • General Purpose Current Sensing and Monitoring